IP66 防水防尘等级,C5 防腐蚀等级
远程配置和升级
兼容宽电网电压和高谐波电网环境
DC/AC SPD 可选,AFCI 检测可选
支持输出功率控制
Model | AU100K3P-HV | AU125K3P-HV | AU136K3P-HV |
Input | |||
Max. DC input power | 150KW | 187.5KW | 204KW |
Max. DC input voltage | 1100V | ||
Max. DC input current | 30AX10 | ||
MPPT voltage range | 200~1000V | ||
Recommended MPP operating voltage | 720V | ||
No. of MPPT | 10 | ||
Max. no. of strings per MPPT | 2 | ||
Output | |||
Rated output power | 1100V | 125KW | 136KW |
Max. output power | 110KVA | 137.5KVA | 149.5KVA |
Max. output current | 127A | 158.8A | 172.6A |
Rated grid voltage | 500V | ||
Grid voltage range | 422~550Vac | ||
Rated grid frequency | 50Hz/60Hz | ||
Grid frequency range | 45~55Hz/55~65Hz | ||
THD | < 2% (Under the rated power) | ||
Power factor | >0.99(rated power) /0.8 leading ~ 0.8 lagging | ||
DC current injection | < 0.5% (Under the rated power) | ||
System data | |||
Max. efficiency | 98.9% | 98.9% | 98.9% |
Euro. efficiency | 98.3% | 98.4% | 98.4% |
Humidity range | 0-100% non-condensing | ||
Cooling type | Intelligent forced air cooling | ||
Temperature range | -25~+60℃ | ||
Power consumption at night | < 1W | ||
Max. working altitude | 4000m | ||
Display | LED/LCD(optional) | ||
Communication interface | RS485/Wifi/GPRS(optional) | ||
Protection | |||
DC reverse-polarity protection | Yes | ||
Short circuit protection | Yes | ||
Output over current protection | Yes | ||
Output over voltage protection | Yes | ||
Insulation resistance monitoring | Yes | ||
Residual current detection | Yes | ||
Surge protection | Yes | ||
Grid monitoring | Yes | ||
Islanding protection | Yes | ||
Temperature protection | Yes | ||
Integrated DC switch | Yes | ||
Mechanical data | |||
Dimensions (WxHxD) | 1050x620x333mm | ||
Weight | 89Kg | ||
Protection class | IP66 | ||
Standard | |||
Grid-connected standard | NB/T 32004-2018;IEC61727 | ||
Safety standard | NB/T 32004-2018;IEC 62109-1/2 | ||
Electromagnetic compatibility | IEC61000-6-2/4 |